Details
Fluke CNX 3000 Industrial System
CNX 3000 Wireless Multimeter
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).| Detailed Specifications | |||
| AC Voltage | |||
| Range ¹ | Resolution | Accuracy ² ³ | |
| 45 Hz to 500 Hz | 500 Hz to 1 kHz | ||
| 600.0 mV | 0.1 mV | 1.0 % + 3 | 2.0 % + 3 |
| 6.000 V | 0.001 V | ||
| 60.00 V | 0.01 V | ||
| 600.0 V | 0.1 V | ||
| 1000 V | 1 V | ||
| ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range. ² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. |
|||
| DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |||
| Function | Range | Resolution | Accuracy |
| mV | 600.0 mV | 0.1 mV | 0.09 % + 2 |
| V | 6.000 V | 0.001 V | 0.09 % + 2 |
| 60.00 V | 0.01 V | ||
| 600.0 V | 0.1 V | ||
| 1000 V | 1 V | 0.15 % + 2 | |
| Ω | 600 Ω | 1 Ω | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. |
| Ω | 600.0 Ω | 0.1 Ω | 0.5 % + 2 |
| 6.000 kΩ | 0.001 kΩ | 0.5 % + 1 | |
| 60.00 kΩ | 0.01 kΩ | ||
| 60.00 kΩ | 0.1 kΩ | ||
| 600.0 kΩ | 0.001 MΩ | ||
| 50.00 MΩ | 0.01 MΩ | 1.5 % + 3 | |
| Diode test | 2.000 V | 0.001 V | 1 % + 2 |
| µF | 1000 nF | 1 nF | 1.2 % + 2 |
| 10.00 μF | 0.01 μF | ||
| 100.0 μF | 0.1 μF | ||
| 9999 μF¹ | 1 μF | 10 % typical | |
| ¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2. | |||
View more about FLUKE CNX 3000 INDUSTRIAL SYSTEM on main site